• HOME
  • Company Profile
  • Products
    • Resistive Load Bank
    • DC Load Bank
    • Portable Load Bank
    • High Voltage Load Bank
    • Generator Load Bank
    • Marine Load Bank
    • RCD Load Bank
    • Data Center Load Bank
    • UL Switching Load Bank
    • RLC load bank
    • RL load bank
  • Blog
  • contacts
  • More
    • HOME
    • Company Profile
    • Products
      • Resistive Load Bank
      • DC Load Bank
      • Portable Load Bank
      • High Voltage Load Bank
      • Generator Load Bank
      • Marine Load Bank
      • RCD Load Bank
      • Data Center Load Bank
      • UL Switching Load Bank
      • RLC load bank
      • RL load bank
    • Blog
    • contacts

+8618917375727

+8618917375727

  • HOME
  • Company Profile
  • Products
    • Resistive Load Bank
    • DC Load Bank
    • Portable Load Bank
    • High Voltage Load Bank
    • Generator Load Bank
    • Marine Load Bank
    • RCD Load Bank
    • Data Center Load Bank
    • UL Switching Load Bank
    • RLC load bank
    • RL load bank
  • Blog
  • contacts

GLOBAL LOAD BANK MANUFACTURER


CUSTOM R&D

REGISTER

REGISTER TO OBTAIN OUR QUOTATIONS OF load bank , SPECIFICATIONS AND CUSTOMIZATION SOLUTIONS

BLOG OF LOAD BANK

FAQ ABOUT LOAD BANKS

Should you fail to find a relevant answer, feel free to email us at sales@topsteloadbanks.com. 

1. Confirm Working Voltage

  •  Standard low voltage AC: 380V / 400V / 415V / 480V, for industrial generators and mains power systems.
  • Medium & High Voltage: 3.3kV /6kV / 10kV / 10.5kV /11kV / 35kV, designed for power plants, wind farms and substation commissioning.
  • DC Load Bank: 12V / 24V / 48V / 110V / 220V / 400V / 800V / 1000V, applied to battery discharging, EV chargers, energy storage and telecom power supplies.
  • Special Custom Voltage: 400Hz aviation 115/200V, marine 440V/450V, data center 208V, etc.

2. Determine Required Power Rating

  • For generator testing: Rated power of load bank shall be 80%~100% of generator rated power to support full-load aging test.
  •  For UPS & backup power acceptance: Match UPS rated capacity, with support for 50% load, 100% full load and 125% short-time overload test.
  •  For battery & EV charger discharge: Calculate power based on max voltage and current with 10% power margin.
  •  For power plant & offshore project: Adopt containerized modular load banks, which allow parallel connection for capacity expansion.

3. Choose Load Type

  • Resistive Load Bank: Most widely used for basic acceptance of generators, UPS and shore power.
  • Resistive-Inductive (RL) Load: Simulate inductive loads such as pumps and fans, ideal for marine and motor-driven power systems.
  • RLC Resistive-Inductive-Capacitive Load: Adjustable leading/lagging power factor, used for anti-islanding test and reactive power calibration of inverters.
  • RCD Non-linear Load: Simulate distorted current of servers and switching power supplies, mainly for type approval of UPS and inverters.
  • DC Load Bank: Only applicable to DC circuit discharge and performance inspection, never connect to AC power.

4. Select Structure According to Application

  •  Wheeled Portable Type: 10–200kW, easy to move for temporary workshop & on-site inspection.
  • 19-inch Rack Mount Type: Installed inside data center cabinets, low noise and dustproof for permanent aging test.
  •  Cabinet Fixed Type: 200–1000kW, for long-term fixed use in factories.
  •  Containerized Integrated Type: 500kW–10MW, IP56 waterproof & anti-corrosion, for outdoor power stations, offshore platforms and wind farms.

5. Environmental Protection Grade

  •  Indoor data center: IP54 dust-proof and low-noise model is acceptable.
  • Open air, dock and marine environment: IP56 or above with salt-spray anti-corrosion treatment is mandatory.
  • Extreme high/low temperature areas: Customize enhanced cooling and cold-start function.

6. Control & Optional Functions

  • Basic: Manual step load adjustment via buttons. Advanced options: Local touch screen, PC upper computer software, remote Ethernet/WiFi control, automatic test report generation. Additional modules for temperature rise recording, harmonic analysis and data storage are available on request.


Quality First, Customer First

  • Company Profile
  • Resistive Load Bank
  • DC Load Bank
  • Portable Load Bank
  • High Voltage Load Bank
  • Generator Load Bank
  • Marine Load Bank
  • RCD Load Bank
  • Data Center Load Bank
  • UL Switching Load Bank
  • RLC load bank
  • RL load bank
  • Blog
  • contacts

Suzhou Lingding Electrical Technology Co., Ltd.

+8618917375727

 Copyright © Suzhou Lingding Electrical Technology Co., Ltd. All Rights Reserved. 

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept

Topste load banks

Contact Now