SUZHOU LINGDING ELECTRICAL TECHNOLOGY CO., LTD.

WhatsApp:+8618917375727

  • HOME
  • Company Profile
  • Products
    • Resistive Load Bank
    • DC Load Bank
    • Portable Load Bank
    • High Voltage Load Bank
    • Generator Load Bank
    • Marine Load Bank
    • RCD Load Bank
    • Data Center Load Bank
    • UL Switching Load Bank
    • RLC load bank
    • RL load bank
  • Blog
  • contacts
  • 更多
    • HOME
    • Company Profile
    • Products
      • Resistive Load Bank
      • DC Load Bank
      • Portable Load Bank
      • High Voltage Load Bank
      • Generator Load Bank
      • Marine Load Bank
      • RCD Load Bank
      • Data Center Load Bank
      • UL Switching Load Bank
      • RLC load bank
      • RL load bank
    • Blog
    • contacts

WhatsApp:+8618917375727

  • HOME
  • Company Profile
  • Products
    • Resistive Load Bank
    • DC Load Bank
    • Portable Load Bank
    • High Voltage Load Bank
    • Generator Load Bank
    • Marine Load Bank
    • RCD Load Bank
    • Data Center Load Bank
    • UL Switching Load Bank
    • RLC load bank
    • RL load bank
  • Blog
  • contacts

GLOBAL LOAD BANK MANUFACTURER


CUSTOM R&D

REGISTER

REGISTER TO OBTAIN OUR QUOTATIONS OF load bank , SPECIFICATIONS AND CUSTOMIZATION SOLUTIONS

BLOG OF LOAD BANK

FAQ ABOUT LOAD BANKS

Should you fail to find a relevant answer, feel free to email us at sales@topsteloadbanks.com. 

1. Confirm Working Voltage

  •  Standard low voltage AC: 380V / 400V / 415V / 480V, for industrial generators and mains power systems.
  • Medium & High Voltage: 3.3kV /6kV / 10kV / 10.5kV /11kV / 35kV, designed for power plants, wind farms and substation commissioning.
  • DC Load Bank: 12V / 24V / 48V / 110V / 220V / 400V / 800V / 1000V, applied to battery discharging, EV chargers, energy storage and telecom power supplies.
  • Special Custom Voltage: 400Hz aviation 115/200V, marine 440V/450V, data center 208V, etc.

2. Determine Required Power Rating

  • For generator testing: Rated power of load bank shall be 80%~100% of generator rated power to support full-load aging test.
  •  For UPS & backup power acceptance: Match UPS rated capacity, with support for 50% load, 100% full load and 125% short-time overload test.
  •  For battery & EV charger discharge: Calculate power based on max voltage and current with 10% power margin.
  •  For power plant & offshore project: Adopt containerized modular load banks, which allow parallel connection for capacity expansion.

3. Choose Load Type

  • Resistive Load Bank: Most widely used for basic acceptance of generators, UPS and shore power.
  • Resistive-Inductive (RL) Load: Simulate inductive loads such as pumps and fans, ideal for marine and motor-driven power systems.
  • RLC Resistive-Inductive-Capacitive Load: Adjustable leading/lagging power factor, used for anti-islanding test and reactive power calibration of inverters.
  • RCD Non-linear Load: Simulate distorted current of servers and switching power supplies, mainly for type approval of UPS and inverters.
  • DC Load Bank: Only applicable to DC circuit discharge and performance inspection, never connect to AC power.

4. Select Structure According to Application

  •  Wheeled Portable Type: 10–200kW, easy to move for temporary workshop & on-site inspection.
  • 19-inch Rack Mount Type: Installed inside data center cabinets, low noise and dustproof for permanent aging test.
  •  Cabinet Fixed Type: 200–1000kW, for long-term fixed use in factories.
  •  Containerized Integrated Type: 500kW–10MW, IP56 waterproof & anti-corrosion, for outdoor power stations, offshore platforms and wind farms.

5. Environmental Protection Grade

  •  Indoor data center: IP54 dust-proof and low-noise model is acceptable.
  • Open air, dock and marine environment: IP56 or above with salt-spray anti-corrosion treatment is mandatory.
  • Extreme high/low temperature areas: Customize enhanced cooling and cold-start function.

6. Control & Optional Functions

  • Basic: Manual step load adjustment via buttons. Advanced options: Local touch screen, PC upper computer software, remote Ethernet/WiFi control, automatic test report generation. Additional modules for temperature rise recording, harmonic analysis and data storage are available on request.


Quality First, Customer First

  • Company Profile
  • Resistive Load Bank
  • DC Load Bank
  • Portable Load Bank
  • High Voltage Load Bank
  • Generator Load Bank
  • Marine Load Bank
  • RCD Load Bank
  • Data Center Load Bank
  • UL Switching Load Bank
  • RLC load bank
  • RL load bank
  • Blog
  • contacts

Suzhou Lingding Electrical Technology Co., Ltd.

+8618917375727

 Copyright © Suzhou Lingding Electrical Technology Co., Ltd. All Rights Reserved. 

此网站使用 Cookie。

我们使用 cookie 来分析网站流量并优化您的网站体验。通过接受我们对 cookie 的使用,您的数据将与所有其他用户数据进行汇总。

接受

Topste load banks

Contact Now